Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Reflections on shiny metal surfaces cause defects to be missed, but a polarizing filter removes themA 0.1 mm groove is visible in the image but can’t be measured: how to get both sharpness and depth from the same microscopeMeasure directly in the image: no more guessing the magnification or fighting reflections during microscopic inspectionSee inside the machine without taking it apart: a camera in the tip gives a sharper image than fiber opticsReflections hide the flaw: how to see scratches, burrs and solder defects on shiny surfacesSpotting the fault in the pipe before you tear up the floor saves more than the repair itselfShiny metal surfaces hide scratches and cracks until the reflections disappear from the imageSee what’s behind the hole: documented inspection of tight spaces without disassemblySharp Images of Shiny Surfaces: How to See Scratches and Pores That Ordinary Light HidesShiny metal surfaces can be measured: how to remove reflections from the microscope imageVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Reflections on shiny metal surfaces cause defects to be missed, but a polarizing filter removes themA 0.1 mm groove is visible in the image but can’t be measured: how to get both sharpness and depth from the same microscopeMeasure directly in the image: no more guessing the magnification or fighting reflections during microscopic inspectionSee inside the machine without taking it apart: a camera in the tip gives a sharper image than fiber opticsReflections hide the flaw: how to see scratches, burrs and solder defects on shiny surfacesSpotting the fault in the pipe before you tear up the floor saves more than the repair itselfShiny metal surfaces hide scratches and cracks until the reflections disappear from the imageSee what’s behind the hole: documented inspection of tight spaces without disassemblySharp Images of Shiny Surfaces: How to See Scratches and Pores That Ordinary Light HidesShiny metal surfaces can be measured: how to remove reflections from the microscope image

With two spindles, each point on the sample becomes a coordinate pair

Published August 27, 2026 at 22:31

If you move the sample by hand under a microscope, there is no good vocabulary to describe where anything is. ”A bit to the left, near the top edge” is enough to point at it, but not enough to return to it — and certainly not enough to describe the distance between two features.

An XY stage gives the sample a coordinate system. Two mechanical micrometer spindles with 0.01 mm resolution ensure that every point has a defined position in X and Y, and consequently a name you can write down.

Korsbord MT-25 med tvaa maetspindlar foer finpositionering

What it is

An XY stage for fine positioning designed for the Kitozoom system.

  • Travel range 25 x 25 mm
  • Two mechanical micrometer spindles with 0.01 mm resolution
  • Top plate 85 x 85 mm with four M4 threads at 60 mm pitch for fixtures
  • Can be combined with the RT-85 rotary stage
  • Compatible only with the KITO 10 model and KT-100

Measuring with the spindle instead of the image

There are two ways to measure a distance under a microscope. One is measuring directly in the image: the software converts pixels to millimeters, which requires the calibration to be valid for the exact magnification setting currently in use.

The other is measuring with the stage. You align the crosshair with the first feature, read the spindles, travel to the second feature, and read them again — the difference is your distance. This measurement is mechanical and does not care at all about the optical magnification setting. The crosshair only needs to tell you ”here”, not ”how far”.

This is a valuable characteristic, as an adjusted zoom setting without recalibration is otherwise a silent source of error. When measuring with the spindles, that source of error simply does not exist.

Systematic scanning instead of searching

Searching through a sample manually is unreliable. You cover some areas twice while missing others entirely, and afterward, there is no way of knowing which was which. With an XY stage, you can instead scan row by row at set increments — making the inspection complete, repeatable, and straightforward for someone else to replicate.

The same applies in reverse: once you have found something and recorded its coordinates, you can return to that exact point a week later, or have a colleague do it.

The four threads are the understated detail

M4 holes at a 60 mm pitch mean the stage is designed to carry fixtures. A simple plate with a mechanical stop ensures that a component sits in the exact same position every time it is placed — and only then do coordinates become comparable between different units, not just within a single one.

Adding the rotary stage introduces a third degree of freedom. X, Y, and rotation angle allow you to align the part precisely, rather than having to compensate for how it happened to land.

And the honest limitation: 25 x 25 mm is a fine-positioning range, not a large measuring stage. Anything larger must be moved by hand, which resets your reference zero. Furthermore, the stage fits only specific models in the system — well worth verifying beforehand, as a positioning stage that doesn’t fit is of no use at all.

Three typical use cases

  • PCB inspection: systematic scanning with the ability to return to a recorded point.
  • Small parts measurement: distances between features, measured directly with the spindles.
  • Series of identical objects: mounting a fixture on the stage ensures consistent positioning for every unit.

Why it pays off

What sets a proper inspection apart from a mere impression is repeatability. An observation without a documented position is hard to verify, difficult to hand over, and impossible to track over time — regardless of how good the optics are.

An XY stage costs a fraction of the microscope it sits beneath, serving as another example of a familiar pattern: the low-cost part of the setup is often the one that dictates which questions the expensive part can answer.