Hoppa till innehåll
Free shipping on orders over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to See Inside an Engine or Piping System Without Disassembling AnythingReflections on shiny surfaces hide the scratch you are looking for, and the polarizing filter in a digital microscope removes themMeasuring What the Eye Can’t Judge: How to Read Hundredths of a Millimeter Right at the WorkstationWhy your reading is wrong when you read a scale with an ordinary loupe, and how telecentric optics remove the errorWhat You Can’t See Around the Corner Costs More Than What You Dismantle to Get AccessSee the solder joint and surface defect on a screen instead of through a magnifier, and document it right awayReflections on shiny metal surfaces cause defects to be missed, but a polarizing filter removes themA 0.1 mm groove is visible in the image but can’t be measured: how to get both sharpness and depth from the same microscopeMeasure directly in the image: no more guessing the magnification or fighting reflections during microscopic inspectionSee inside the machine without taking it apart: a camera in the tip gives a sharper image than fiber opticsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to See Inside an Engine or Piping System Without Disassembling AnythingReflections on shiny surfaces hide the scratch you are looking for, and the polarizing filter in a digital microscope removes themMeasuring What the Eye Can’t Judge: How to Read Hundredths of a Millimeter Right at the WorkstationWhy your reading is wrong when you read a scale with an ordinary loupe, and how telecentric optics remove the errorWhat You Can’t See Around the Corner Costs More Than What You Dismantle to Get AccessSee the solder joint and surface defect on a screen instead of through a magnifier, and document it right awayReflections on shiny metal surfaces cause defects to be missed, but a polarizing filter removes themA 0.1 mm groove is visible in the image but can’t be measured: how to get both sharpness and depth from the same microscopeMeasure directly in the image: no more guessing the magnification or fighting reflections during microscopic inspectionSee inside the machine without taking it apart: a camera in the tip gives a sharper image than fiber optics

Reflections on shiny surfaces hide the scratch you are looking for, and the polarizing filter in a digital microscope removes them

Published 20 November 2026 at 23:37

You are holding a ground shaft journal under the work lamp and see something that might be a scratch. You tilt the part, and the scratch disappears in the reflection. You tilt it back, and it looks like a shadow. After a while the question is no longer whether the part passes, but whether you are seeing what you should be seeing at all. It is a common situation when inspecting shiny surfaces, and a magnifying glass rarely solves it.

Dino-Lite EDGE, 5 Mpixels, mätfunktion, FLC, polarisator, metall

What the product is

The Dino-Lite EDGE AM7115MZT is a 5-megapixel handheld digital microscope with a magnification range of 10 to 220x. It comes in an aluminum housing and connects to a computer, where the image is displayed live and can be saved. Three features set it apart from simpler models: a built-in polarizer, flexible LED control (FLC) and measurement functions with calibration in the software.

What problems it solves

The polarizer filters out the direct light that bounces off shiny surfaces. The reflection on metal, plastic, glass or a solder joint is reduced, and surface texture, scratches and cracks become visible. With FLC you can also control which part of the LED ring is lit, so you can illuminate from the side and bring out relief instead of flooding the surface with light. The measurement functions let you measure a defect directly in the image instead of estimating it by eye.

When and why it is used

The microscope is used when an assessment must be possible to present and repeat: during incoming inspection, in complaint cases, in troubleshooting and in quality documentation. The image is saved together with the measurement, so the next person sees the same thing you did. The front caps are interchangeable, which is helpful when the microscope is hand-held or mounted in a stand.

Three areas of use

Machine shop industry. Inspection of surface finish, deburring and tool wear on ground and milled parts. The polarizer lets you see the edge of a cutting edge or a scratch in a chamfered surface without having to search for the right lighting angle.

Electronics. Assessment of solder joints, contact surfaces and component markings. Shiny solder is a typical reflection problem, and with the measurement function you can check the distance between leads or the width of a trace.

Maintenance and failure analysis. Examination of fracture surfaces, corrosion damage and wear marks on bearings, shafts and sealing surfaces. The images can be attached to the report and compared at the next service.

Why it pays off

The cost in inspection rarely lies in the instrument but in the uncertainty. A part that is rejected unnecessarily becomes scrap, and a defect that is missed comes back as a complaint or downtime. A microscope that provides a clear, measurable and saved image shortens assessment time, reduces discussions about what is actually visible and provides documentation when you need to talk to a supplier. You also do not have to send parts for external analysis for every doubtful case.

If you often inspect shiny surfaces and want measurable, documentable images, you can read more about the Dino-Lite EDGE AM7115MZT.