Hoppa till innehåll
Free shipping on orders over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Sharp images of shiny surfaces without the tool hitting the lensHow to measure ±5 µm on a 30 mm wide part without losing resolutionMeasurement errors under a microscope are often caused by the magnification not matching the calibrationHow to See Inside an Engine or Piping System Without Disassembling AnythingReflections on shiny surfaces hide the scratch you are looking for, and the polarizing filter in a digital microscope removes themMeasuring What the Eye Can’t Judge: How to Read Hundredths of a Millimeter Right at the WorkstationWhy your reading is wrong when you read a scale with an ordinary loupe, and how telecentric optics remove the errorWhat You Can’t See Around the Corner Costs More Than What You Dismantle to Get AccessSee the solder joint and surface defect on a screen instead of through a magnifier, and document it right awayReflections on shiny metal surfaces cause defects to be missed, but a polarizing filter removes themVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Sharp images of shiny surfaces without the tool hitting the lensHow to measure ±5 µm on a 30 mm wide part without losing resolutionMeasurement errors under a microscope are often caused by the magnification not matching the calibrationHow to See Inside an Engine or Piping System Without Disassembling AnythingReflections on shiny surfaces hide the scratch you are looking for, and the polarizing filter in a digital microscope removes themMeasuring What the Eye Can’t Judge: How to Read Hundredths of a Millimeter Right at the WorkstationWhy your reading is wrong when you read a scale with an ordinary loupe, and how telecentric optics remove the errorWhat You Can’t See Around the Corner Costs More Than What You Dismantle to Get AccessSee the solder joint and surface defect on a screen instead of through a magnifier, and document it right awayReflections on shiny metal surfaces cause defects to be missed, but a polarizing filter removes them

Sharp images of shiny surfaces without the tool hitting the lens

Published November 23, 2026 at 5:48 pm

Most people who inspect small details have been through it: you lower the microscope towards a circuit board or a machined surface, and just as the image becomes sharp, the lens is so close that there is no room for the tweezers or the soldering iron. On top of that, the metal glares so much that the detail you are interested in is lost in a white reflection. All that remains is to pause the work, put down the tool, look, and start over.

Dino-Lite EDGE, 1,3 Mpixels, trådlös exkl. WiFi-modul, långt fokusavstånd, mätfunktion, FLC, polarisator

What it is

The Dino-Lite AF4115ZTL is a digital microscope in the LWD series, meaning it has a long working distance. It connects to a PC or Mac via USB and delivers a live image of 1.3 megapixels (1280×1024) at up to 30 frames per second. Magnification ranges from 10x to 140x. The microscope has an integrated polarizer, eight white LEDs with flexible light control (FLC) and measurement functions in the software. If you want to do without the cable, there is a wireless solution with the optional WF-20.

What problems it solves

The working distance is what sets this model apart from a standard microscope. At low magnification it is over 20 cm, and at 100x to 140x there is still about 30 mm between the lens and the object. That is enough room for tweezers, a probe or a small screwdriver. The polarizer reduces reflections from metal, plastic and solder, so that surface structure and cracks are visible instead of the glare. With the measurement function you can also take a measurement directly in the image, after calibration against the supplied scale.

Practical use cases

In the electronics workshop, the microscope is used to inspect solder joints, cold joints and bridges between the pins of small packages. Since you view the image on screen, you can rework the component while you look, without leaning over an eyepiece.

In the engineering and machining industry, it is used to check cutting edges, burrs on milled edges and surface finish on shiny parts. The polarizer lets you assess wear and scratches without the surface glaring. An edge width or a scratch depth can be measured and saved as an image together with the measurement.

In quality control and incoming inspection, for example on welded joints, pressed fittings in plumbing installations or gasket surfaces, you document the deviation with an image instead of a verbal description. The same image can be forwarded to the supplier.

Why it pays off

The savings are seldom in the microscope itself but in the time around it. Not having to move the tool out of the way for every inspection shortens rework. A clear image with measurements means that complaints and deviations can be settled straight away, and that several people can make the same assessment without standing at the same bench. This reduces the number of misjudgments, and a single rejected batch avoided can often outweigh the purchase price.

Next steps

If you often work with shiny parts or need to get tools in under the microscope, a model with a long working distance and a polarizer is a reasonable choice. See specifications, working distance per magnification and accessories on the product page.